This model of ACE burn off oven is popular for its several beneficial features. The oven is equipped with a central heat distribution system. This ensures even distribution of temperature throughout the oven chamber. Also, primary and secondary water suppression systems effectively manage heat inside the chambers, eliminating distortion/damage of parts during the heat cleaning process.
The primary burner of 3175-RT oven operates at 800°F (427°C). Volatile materials are converted into smoke due to this high temperature. The afterburner, which operates at 1,400°F (742°C) burns off the hazardous smoke and gases produced at the primary burner. Only water vapor and carbon Dioxide are discharged to atmosphere, making it an environmentally sustainable product.
| Physical | |
| Component | Specifications |
|
Inside Dimensions W/O Cart |
60"W x 60"D x 96"H |
|
Inside Dimensions With Cart |
60"W x 60"D x 81"H |
|
Volume Over Cart |
169 CU. FT. |
|
Single Platform Cart Dimensions |
57"W x 57"D x 15"H |
|
Outside Dimensions |
80"W x 94"D x 109"H |
|
Shipping Weight |
4,400 LBS. |
|
Location of Controls |
Right Side |
|
Location of Exhaust Stack |
Top Rear Left Corner |
|
Exhaust Stack |
12" ID x 10' Included |
|
Exhaust Stack |
18" OD x 10' Included |
| Controls | |
| Component | Specifications |
|
Primary Burner - Normal |
800°F (427°C) |
|
Afterburner - Normal |
1,400°F (742°C) |
|
Over Temp. Control |
Standard |
|
NFPA-86A Specifications |
Optional |
|
Primary Water Spray |
Standard |
|
Secondary Water Spray |
Standard |
|
FM Specifications |
Optional OA-2600 |
|
ISO Control Certified |
Standard |
|
Primary Burner off on Loss of A.B. |
Standard |
|
Primary & A.B. Burners Rated For |
800,000 BTU/HR |
|
Automatic Shutoff System |
Standard |
|
One Touch Control (OTC) System |
Optional |
|
High Fire Afterburner 1,500°F (798°C) |
Optional |
| Construction | |
| Component | Specifications |
|
Cart Rating |
8,000 LBS. |
|
Cart 3" Structural Channel |
5 LBS/FT |
|
Oven Steel Enclosure |
11 Ga. CRS |
|
Oven Enclosure Front Face |
1/4" CRS Plate |
|
Angle Iron Reinforced Enclosure |
Standard |
|
Blanket Insulation 4" Thick 2,300°F. |
Standard |
|
Aluminized Coating Inside Enclosure |
Standard |
|
Steel Floor Covers Over 4" Insulation |
3/16" CRS |
|
Exterior Finish Hi-Temp. |
Blue Enamel |
|
Exhaust Stack Insulation Rated |
2,700°F. 2" Thick |
|
1 Top Mounted Pressure Relief Hatch |
13.74 SQ. FT. |
|
Oven Volume 204.69 CU. FT. |
1:14.90 Vent Ratio |
|
Qty Primary Water Nozzles |
2 Standard |
|
Qty Secondary Water Nozzles |
4 Standard |
|
Qty Primary Burners |
1 Standard |
|
Qty Afterburners |
1 Standard |
|
NFPA Preferred Vent Ratio |
1:15 |
| Sr. No. | Electric | Water | Fuel | |||
| Component | Specifications | Component | Specifications | Component | Specifications | |
| 1 |
Voltage/Phase/Hertz |
120/1/60 |
Normal |
Less Than 3.6 Gal/HR. |
Primary Burner Input |
200,000 BTU/HR |
| 2 |
Amps |
* 5 to 10 |
Capacity |
6 Gal./HR. Ea. Nozzle |
Afterburner Input |
425,000 BTU/HR |
| 3 |
|
|
Min/Max Pressure |
30 to 60 PSI |
Natural Gas Inlet Pressure |
8" to 14" W.C. |
| 4 |
|
|
|
|
Propane Inlet Pressure |
12" to 18" W.C. |
| 5 |
|
|
|
|
Gas Inlet Pipe Size |
1-1/4" |